ERR_WIS_30271 - Maximum binary output size limit reached

Maximum binary output size limit reached (ERR_WIS_30271)

Environment SAP BI 4 SP 8

While exporting a huge  Web Intelligence report in Excel format BO raised the error:
Max Binary file size limit exceeded. The document is too large to be processed by the server. Error WIS 30271 


Cause

This error message appears because BusinessObjects Enterprise allows documents to be saved with the limit specified for Web Intelligence Report server settings in the Central Management Console(CMC).
To resolve the error follow the below steps:
- Login to Central Management Console (CMC) using BusinessObjects Enterprise "Administrator".
- Navigate to "Home >> Servers".
- Click on "WebIntelligenceProcessingServer" to open its properties.

Increase:
Maximum Character Stream Size (MB)
which specifies the maximum character stream size sent to the Web Intelligence client.
Default value is 5. The valid range is 1 to 65535 MB.

Binary Stream Maximum Size (MB)
which s
pecifies the maximum size, in MB, of a binary stream sent to the Web Intelligence client.

Default value is 50. The valid range is 1 to 65535 MB.

- Click on "Apply" and then on "Update".
- Allow the Web Intelligence server to restart.




Increasing these values too high could impact Web Intelligence performance when users attempt to save excessively large files.